boardhome
Today's Date:
Board Meetings
          Calendar
          Agendas
          Minutes
          Board Members
Licensure
          Licensee Lookup
          Licensure with the Board
          Applications and Forms
          Fees
          Education
          FAQ
          Renew Your License
          Change Your Address
          Application status
          Print copy of your license
Information
          Laws and Policies
          Publications / News
          FOIA Requests
          Related Links
          License Status Changes
Complaints / Board Orders
          File a Complaint
          Board Orders
          What can I expect when a complaint
          is filed against me?
Contact Us
        Board Email:Contact.BCC@llr.sc.gov
        Board Phone:(803) 896-4688
        Administrator:Roger K. Lowe
        Board Staff: Teresa Martin
        Board Staff:Jennie Meade
        Advice Counsel:   Georgia Lewis   **
        Directions:110 Centerview Dr, Columbia SC

**The Office of Advice Counsel is responsible for
providing legal advice to all Boards, Commissions
and Panels. These attorneys do not provide legal
advice to parties outside LLR.
License Status Changes

South Carolina Building Codes Council

New Federal Appliance Manufacturing Standards

The US Department of Energy (DOE) issued new manufacturing standards, effective January 23, 2006, for residential central air-conditioners and heat pumps. The new standards preempt conflicting requirements in the 2003 edition of the International Energy Conservation Code (IECC).

The effect of the new standards will be to require all residential central air-conditioners and heat pumps manufactured on or after January 23, 2006, to have an increased minimum Seasonal Energy Efficiency Ratio (SEER) and a minimum Heating Seasonal Performance Factor (HSPF). Equipment manufactured in compliance with the 2003 edition of the IECC prior to January 23, 2006, however, can still be sold and installed until the stock is depleted.

The Building Codes Council will not have the opportunity to modify the IECC until it reviews the 2006 edition for adoption. Since compliance of the new standards will be at the manufacturing level, the impact, on code enforcement officers and builders during that interim period should be minimal, if any at all. The conflicting requirements in the IECC will be in Table 503.2 as illustrated below. The words in bold type represent the amended language.

TABLE 503.2
MINIMUM EQUIPMENT PERFORMANCE

EQUIPMENT CATEGORY

SUBCATEGORYe

REFERENCED STANDARD

MINIMUM PERFORMANCEf

Air-cooled heat pumps, Heating mode<65,000 Btu/h cooling capacity, single phase Split systems and single package
Through-the-wall split systems
Through-the-wall single package
ARI 210/240 7.7 HSPF a,b
7.1 HSPF a,b
7.0 HSPF a,b
Gas-fired or oil-fired furnace <225,000 Btu/h DOE 10CFR Part 430, Subpart B, Appendix N AFUE 78% b
E, 80% c
Gas-fired or oil-fired steam and hot-water boilers <300,000 Btu/h DOE 10CFR Part 430, Subpart B, Appendix N AFUE 80% b,d
Air-cooled air conditioners and heat pumps. Cooling mode <65,000 Btu/h cooling capacity, single phase Split systems and single package
Through-the-wall split systems g
Through-the-wall single package g
ARI 210/240 13.0 SEER b
10.9 SEER b
10.6 SEER b

For SI: British thermal unit per hour = 0.2931 W.
a. For multicapacity equipment, the minimum performances shall apply to each capacity step provided. Multicapacity refers to manufacturer-published ratings for more than one capacity mode allowed by the product's controls,
b. This is used to be consistent with the National Appliance Energy Conservation Act (NAECA) of 1987 (Public Law 100-12), as amended.
c. These requirements apply to combination units not covered by NAECA (three-phase power or cooling capacity 65,000 Btu/h).
d. Except for gas-fired steam boilers for which the minimum AFUE shall be 75%.
e. Seasonal rating.
f. Heat pumps manufactured before January 23, 2006 may have a HSPF of 6.8 for split systems and 6.7 for single package units, and air conditioners manufactured before January 23, 2006 may have a SEER of 10 for split systems and 9.7 for single package units. Trade-offs between equipment and other building components are not allowed for equipment that does not exceed the minimum in this table.
g. These requirements apply to through-the-wall products with cooling capacities less or equal to 30,000 Btu/h manufactured prior to January 23, 2010.

Synergy Business Park; Kingstree Building
110 Centerview Dr.
Columbia, S.C. 29210
(803) 896-4300 | Office Hours: 8:30 a.m.- 5:00 p.m.

Directions | Site Map | Privacy | Disclaimer | Customer Satisfaction Survey | Contact Us | Other Languages
Report State Agency Fraud (Office of the Inspector General)


The S.C. Department of Labor, Licensing and Regulation is pleased to provide various publications in portable document format (PDF).
You will need Adobe Reader to view and print these publications.